1、 Remote control product features < br / >
The control protocol of graffiti ZigBee 3.0 < br / > was adopted
One key group control equipment on, scene switching < br / >
One key group control equipment shutdown < br / >
● support local matching scene switching and app online matching scene function < br / >
Realize remote control of one-to-one and one to many < br / >
Ultra strong standby, standby current as low as & le; 5ua, up to more than 2 years standby time < br / >
2、 Electrical parameters
&Nbsp; & nbsp; model
DG-M1210A
environment
working temperature
-30~+50℃
Working humidity
20-90% RH (no condensation)
Storage temperature / humidity
-40 ℃ - 80 ℃; 10-90% RH (no condensation)
Atmospheric pressure
86-106KPa
Product function
Communication protocol
ZigBee 3.0
Radio frequency
2.4G
Wireless distance
<30M
standby power
Less than 5ua
Number of remote control keys
Key 4
other
IP level
IP20
Shell material
PC
weight
32g
Package size
145*48*22mm
Product size
128*42*12mm
Base size
60*46*18mm
Warranty Statement
3 years
3、 Appearance size < br / >
Overall dimension of remote control: L / w / h: 128 * 42 * 12mm < br / >
Base size: L / w / h: 60 * 46 * 18mm < br / >
Four equipment distribution network < br / >
1.1 lighting distribution network < br / >
Firstly, it needs to have ZigBee gateway, and then add search sub device under the gateway. The lamps without distribution network will enter the state of ZigBee gateway when they are powered on for the first time, and the state of distribution network reminder is light and dark circulation breathing. The effect of breathing curve is shown in the figure below: < br / >
The effect picture of respiration curve is shown in the following figure: < br / >
a. When the network is not configured, the number of times of continuous switching is & lt; 3. By default, ZigBee gateway is configured (breathing, can not be paired with the remote controller), and it is always on after 3 minutes of timeout (can be paired with the remote controller); < br / > when the network is not configured, ZigBee gateway is configured
b. When there is no distribution network, the number of continuous switching is & gt; = 3, and it is always on (can be paired with the remote controller); < br / >
c. When the distribution network has been installed, switch & lt; 3 times continuously to restore the state before power failure (power failure memory); < br / >
d. When the network has been distributed, switch & gt; = 3 times continuously to enter the state of ZigBee gateway (breathing, not pairing with the remote controller). After waiting for 3 minutes, the lamp will be normally on and the network will be restored, and then it can be paired with the remote controller; < br / >
e. After 5 seconds of power on in the previous step and before 3 minutes of time-out, power off again, and the lamp immediately restores the network. At this time, it can be paired with the remote control.
Note: as long as the lamp is not breathing, it can be paired with the remote control.
1.2 remote control distribution network < br / >
First, you need to have a ZigBee gateway, and then add a search sub device under the gateway. Long press the on + off key of the remote control until the indicator light of the remote control flashes slowly to enter the distribution network state, and then the remote control app distribution network can be completed.
2、 Lamp remote control pairing / de pairing process < br / >
2.1 local pairing < br / >
a. When the lamp is not equipped with ZigBee gateway, long press the on key of the remote control for 3 seconds until the indicator light of the remote control flashes quickly. If the matching is successful, the indicator light of the remote control will be on for 2 seconds, then it will go out, and the lamp will breathe for 3 times. After matching, the state of the lamp is consistent with that of the distribution network, and then you can use the remote control to control the lamp.
Note: the remote controller can only pair one lamp at a time, and the matched lamp can be selected according to the signal strength, that is, the lamp which is close to the remote controller can be paired with the remote controller. The local mode remote controller can add up to 30 lamps, and the local mode only supports one remote controller to control multiple lamps, and does not support multiple remote controllers to control the same lamp.
2.2 local unpaired < br / >
a. When the lamp is not equipped with ZigBee gateway, long press the off key of the remote control for 3 seconds until the indicator light of the remote control flashes quickly. The pairing is successful. The indicator light of the remote control is always on for 2 seconds and then goes out. The lamp breathes for 3 times. After the pairing is removed, the remote control cannot control the lamp.
Note: the remote controller can only unmatch one lamp at a time, and the lamp to be unmatched is selected according to the signal strength, that is, the lamp to be unmatched is selected according to which lamp is close to.
2.3 app online pairing / de pairing < br / >
a. The distribution network of remote control and lamps has been completed on the app, click remote control equipment to enter the remote control panel; < br / >
b. Select the & lt; settings & gt; button in the upper right corner, jump to the control equipment selection page, check the controlled lamps to be paired, and click to complete the pairing. The number of successfully paired devices will be displayed on the & lt; settings & gt; button icon in the upper right corner (when the remote controller does not pair lamps for the first time, click & lt; settings & gt; Button will pop up a prompt box: long press the brightness + - combination key before prompting pairing until the indicator light of the remote control flashes quickly); < br / >
c. Click the & quot; settings & quot; button in the upper right corner to enter the select control device page, where you can add / delete lamps to be paired; < br / >
d. After pairing, you can use the remote control to control the lamp.
Note: local pairing and app online pairing are mutually exclusive, and only one pairing method can be selected at the same time. (when the remote controller completes the distribution network on the app, it can only pair lamps online through the app, and when the remote controller does not complete the distribution network on the app, it can only pair lamps locally.)